Skip to Content

View Additional Section Content

Published on January 24, 2018

Albumin

SIM

10070 

CPT

82040 

Synonyms

none 

Specimen Type

Plasma or serum 

Container

3.5 ml Green - Lithium heparin plasma separator
4.0 ml Gold-top serum separator

Collection Instructions

None

Volume

2 ml plasma or serum
Min: 0.5 ml

Additional Information

Albumin is part of the CMP and Hepatic panel.

Patient Preparation

none

Specimen Processing Instructions

Plasma:  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes
Serum:  Allow to clot.  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes
Centrifuge within 2 hours of collection.

Transport Requirements

Refrigerated

Specimen Stability

Room temperature:  8 hours   Refrigerated: 5 days 

Rejection Criteria

If not centrifuged within 2 hours of collection.

Reference Range

3.5 – 4.9 g/dl

Critical Value

none 

Test Includes

Albumin 

Methodology

Timed endpoint method 

Testing Frequency

Daily, Monday - Sunday 

 

Reviewed By

Sandy Hammett 

Reviewed Date

1-24-18 

Supplemental

  

Reviewed by Sandy Hammett on January 24, 2018

Was this page helpful?

Yes
No

Thank you for your feedback!

Thank you for your feedback and helping us to improve our website.
There will be no additional response.