Ferritin 

SIM

50080 

CPT

82728 

Synonyms

Ferr 

Specimen Type

Serum 

Container

4.0 ml Gold-top serum separator

Collection Instructions

None

Volume

2 ml serum, minimum 0.5 ml

Additional Information

none

Patient Preparation

none

Specimen Processing Instructions

Serum:  Allow to clot. 
Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Centrifuge within 2 hours of collection.

Transport Requirements

Refrigerated

Specimen Stability

Room temperature:  8 hours   Refrigerated: 5 days 

Rejection Criteria

If not centrifuged within 2 hours of collection.

Reference Range

Males =     22 – 322 ng/mL

Females =  10 – 291 ng/mL

Critical Value

none 

Test Includes

Ferritin 

Methodology

Chemiluminescent technology 

Testing Frequency

Daily, Monday - Sunday 

 

Reviewed By

Sandy Hammett 

Reviewed Date

2-2-18

Supplemental

  

Reviewed by Sandy Hammett on February 02, 2018

Was this page helpful?

Yes
No

Thank you for your feedback!

Thank you for your feedback and helping us to improve our website.