Skip to main content
7976
Lab Test Details

Lab Test Details

SIM

13375 

CPT

82374 

Synonyms

CO2 

Specimen Type

Plasma or serum 

Container

 

3.5 ml Green - Lithium heparin plasma separator 
4.0 ml Gold-top serum separator

Collection Instructions

 

None

Volume

 

2 ml plasma or serum 
Min: 0.5 ml

Additional Information

 

None

Patient Preparation

 

None

Specimen Processing Instructions

 

Plasma:  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Serum:  Allow to clot.  Centrifuge at 3380 rpm’s (±100) for a minimum of 10 minutes

Centrifuge within 2 hours of collection.

Transport Requirements

 

Refrigerated

Specimen Stability

Room temperature: 8 hours;  Refrigerated: 48 hours 

Rejection Criteria

 

•  If not centrifuged within 2 hours of collection. 
•  Gross Hemolysis

Reference Range

 

23.0 - 32.6 mmol/L

Critical Value

<11mmol/L and no high Critical result for CO2. 

Test Includes

Carbon Dioxide 

Methodology

Phosphoenolpyruvate Carboxylase 

Testing Frequency

Daily, Monday - Sunday 

 

Reviewed By

Crystal Killian

Reviewed Date

3/17/2021

Supplemental

 

 

  

Reviewed by Crystal M. Killian March 17, 2021